Control Valve Repair That OEM Could Not Fix
Control Valve Repair
A customer recently requested help with a control valve that the OEM could not fix.
Under normal operating conditions, the valve would only open 7-9%. The customer was hoping to get the valve to approximately 30% open so that they could have better control.
We requested stroke and other pertinent info to perform the needed calculations. Our team received the parts on Thursday, calculated the needed changes, manufactured the new parts, and shipped the valve back to the customer in 2 DAYS. This photo shows the parts being blue checked.
Some words from the happy customer – “You guys did an excellent job, thoroughly impressed. The valve now operates between 30-40% and works flawlessly.”
The customer has requested to order a spare set of valve parts in our TrimKit program. Another successful project in the books!